CA 757
Reference P01191757
Current testing
Measurement range
via current sensor
500 mA to 300 A
(2 ranges)
Resolution 0.01 A to 0.1 A
DC voltage
Measurement range 3 mV to 1,000 V – 4 ranges
Resolution 1 mV to 1 V
AC voltage
Measurement range 100 mV to 1,000 V – 4 ranges
Resolution 1 mV to 1 V
Operating frequency DC and 50/60 Hz
Impedance 10 MΩ
Non-contact
voltage detection
230 V 50/60 Hz at a distance of approx.
5 cm
Audible
continuity test R ≤ 30 Ω
Resistance testing
Measurement range 0.3 Ω to 30 MΩ – 6 ranges
Resolution 0.1 Ω to 0.01 MΩ
Capacitance testing
Measurement range 400 pF to 30 mF
Resolution 0.001 nF to 0.01 mF
Standards 600 V CAT III, IEC 61010-1, IEC 61010-031,
IEC 61010-032, IEC 61010-033
Power supply 2 x 1.5 V LR03 batteries
Battery life 100 hours with alkaline batteries –
Automatic standby mode after 10 minutes
Dimensions / weight 180 x 52 x 45 mm / 200 g
-
Description
- |
-
Add Tags
- |
Tail sed sausage magna quis commodo snasae. Aliquip strip steak esse ex in ham hock fugiat in. Labore velit pork belly eiusmod ut shank doner capicola consectetur landjaeger fugiat excepteur short loin. Pork belly laboris mollit in leberkas qui. Pariatur snasae aliqua pork chop venison veniam. Venison sed cow short loin bresaola shoulder cupidatat capicola drumstick dolore magna shankle.
AVAILABILITY: In stock
Locate hidden circuits!
Comprising a transmitter and a receiver, the LOCAT-N provides digital, visual and audio indication of the presence of cables or ducts so that you can follow them intuitively.
AVAILABILITY: In stock
The C.A 6418 earth/ground clamp, delivered in its carrying case, can be used for quick testing of earth loops, whatever their type. Its clamping capacity allows measurements on 30 x 40mm and 20 x 55mm rectangular bars and cables 32mm in diameter.
The C.A 6418 clamp simultaneously displays the earth-loop resistance and the leakage current.
Download Sales Brochure
AVAILABILITY: In stock
The CA 6011 continuity tester has been specially designed for periodic testing of the protective earth conductors of electrical equipment, appliances and installations, linked in particular to the standards and regulations: IEC/EN 60364, NF C 15-100, VDE 100, etc.
The CA 6011 continuity tester has been specially designed for periodic testing of the protective earth conductors of electrical equipment, appliances and installations, linked in particular to the standards and regulations: IEC/EN 60364, NF C 15-100, VDE 100, etc.
These systematic, repetitive tests represent more than 80% of testing operations. Particular care must therefore be taken to prevent them from becoming tiresome.
Download Sales Brochure
AVAILABILITY: In stock
Reference P01127012 P01127014
Voltage (UHE)
Range – 0.1-600V
Resolution – 0.1V
Accuracy – ± ( 1% reading + 1 ct)
2P resistance
Range 0.05-99.99 Ω / 80.0-999.9 Ω / 0.800-9.999 kΩ / 8.00-50.00 kΩ
Resolution 0.01 Ω / 1 Ω / 10 Ω / 100 Ω
Accuracy ± ( 2% reading + 10 ct) / ± ( 2% reading + 2 cts) / ± ( 2% reading + 1 ct) / ± ( 2% reading + 1 ct)
Cable compensation – up to 5 Ω
3P earth/ground resistance
Range 0.5 Ω – 2.000 kΩ 0.5 Ω – 50.00 kΩ
Resolution 0.01 Ω / 0.1 Ω / 1 Ω 0.01 Ω / 0.1 Ω / 1 Ω/ 10 Ω
Accuracy ±(1% reading + 10 cts) / ±(1% reading + 2 cts) / ±(1% reading + 1 ct)
Measurement frequency 128 Hz or 256 Hz
Open-circuit voltage ± 10 V peak
AVAILABILITY: In stock
Discover the CA 6418
oblong-headed earth
clamp
AVAILABILITY: In stock
AVAILABILITY: In stock
Voltage
Measurement range / resolution 1-700V / 1V
Accuracy / input impedance ±1.2% reading ± 1pt in AC+DC ; ±1% reading ± 1 ct in DC / 25 MΩ
Operating frequency DC; 30-440 Hz
Insulation
Test voltage 250-500-1000 V
Range at maximum test voltage 11 GΩ
Measurement range 250 V : 50 kΩ – 4,2 GΩ / 500 V : 100 kΩ – 4.2 GΩ / 1,000 V : 200 kΩ – 11 GΩ