• View as:
  • Sidebar
  • Sort by:

AVAILABILITY: In stock


The C.A 6418 earth/ground clamp, delivered in its carrying case, can be used for quick testing of earth loops, whatever their type. Its clamping capacity allows measurements on 30 x 40mm and 20 x 55mm rectangular bars and cables 32mm in diameter.
The C.A 6418 clamp simultaneously displays the earth-loop resistance and the leakage current.

Download Sales Brochure

AVAILABILITY: In stock


CA 1510 CA 1510 black
Reference P01651011 P01651010
Recording intervals Customizable from 1 minute to 2 hours
Storage More than 1 million points
Buzzer and units Yes / °C or °F
Backlighting
/ Hold / Min Max Yes
Dimensions / Weight 125 x 65.5 x 32 mm / 190 g with batteries
Power supply
Batteries: 2 x 1.5V LR6
or rechargeable battery
Mains connection possible
with mains adapter/
micro USB supplied as standard

AVAILABILITY: In stock


J, K, T, N, E, R and S   thermocouples (CA 1821 & CA 1822)
> Pt100 and Pt1000
resistive probes (CA 1823)
> Compact and magnetized for fixed or portable use

> Can record up to 1 million points

 

AVAILABILITY: In stock


Reference P01654110
Measurement range 0.1 to 200,000 lx
0.01 to 18,580 fc
Accuracy in standard mode
Incandescent lamp ± 3 % of reading
LED ± 6 % of reading (3,000 K and 6,000 K)
Fluorescent lamps ± 9 % of the reading
Accuracy in compensation mode
LED mode ± 4 % of the reading (at 4,000 K)
Fluo mode ± 4 % of the reading (type F11, 4,000 K)
Functions Min., Max., HOLD, Average
Recording Manual start and stop on the product
Programmed recording

AVAILABILITY: In stock


> Transformation ratio measurement on
power, voltage and current transformers
> Storage of up to 10,000 measurement
results

AVAILABILITY: In stock


CA 1227
Reference P01654227
Air speed/
flow-rate sensor Vane with optical detection
Air speed range 0.25 m/s to 35.0 m/s (49.0 to 6890.0 fpm)
Air speed accuracy ± 3 % of reading ± 4 cts
Air flow-rate range 0 to 2,999 m3/h
Air flow-rate accuracy ± 8 % of reading
Temp. range °C/°F – 20 to +50 °C / -4 to +122 °F
Temp. accuracy °C 0 to 50 °C: ± 0.8 °C
-20 to 0 °C: ± 1.6 °C
Functions Min., Max., HOLD, Average
Recording Manual start and stop on the product
Programmed recording
Data storage More than 1 million points

AVAILABILITY: In stock


CA 1246
Reference P01654246
Relative Humidity range 3.0 to 98.0 %RH
Relative Humidity
accuracy
10 to 90 %RH: ± (2 %RH ± 1 ct)
outside that range: ± (4 %RH ± 1 ct)
Temperature range – 10.0 to +60.0°C
Temperature
accuracy
10 to 40°C: ± (0.5°C ± 1 ct)
outside that range: ± (0.032 x (T-25) ± 1 ct) /
T= temperature in °C
Dew point range and
accuracy
Dew point: – 20.0 to +60.0 °Ctd
Accuracy: 1.5°C
Functions Min., Max., HOLD, Alarms
Recording Manual start/stop on the product
Programmed recording
Alarms
Visual alert when threshold definable
via Data Logger Transfer is overrun
Recording can be triggered
on the alarm threshold
Battery life 1,000 hrs (portable mode) / 3 years when recording
(measurements every 15 minutes)
Ingress protection IP54
Mounting